Advertise Bulletin Board Downloads Feedback Offers Signin Signout Sitemap Home
 Search For
Building Products - Cement(highstrength_portland_cement)

High strength ordinary portland cement, on water curing gains faster than OPC types and its ultimate strength is also higher. It is used for Structural Concrete, Prestressed Concrete, Bridges, Tunnels etc.  This cement should not have Loss on Ignition of more than 4 % compared to OPC 5% maximum.

 

Properties

 

Specific surface sq cm /gms (minimum)

3500

Setting time (in minutes) (Vicat):

Initial (Maximum) (in minutes)

30 

600

Soundness, Le Chatelier (max.) mm.

10

Heat of hydration

7days (minimum)

28 days (maximum)

 

--

--

Compressive str. Mpa

Min. at               7 days

                       28 days

 

33

43

MgO (%) (max.)

6

SO3 (%) (max.) 

3

Insoluble residue(%)(max.)

2

Loss on ignition(%) (max.)

4